~~NOTOC~~ ===== Afficher températures ===== cprop -summary -c "Temperature" :!: HP-UX 11.31 only ===== Récupérer la configurations hardware et logiciel ===== * 11i-v1 (11.11) print_manifest * 11i-v2 (11.23) machinfo ===== Récupérer les maps hardware d'un serveur ===== echo map | cstm ===== Récupérer la configuration hardware de la mémoire ===== echo "selclass qualifier memory;info;wait;infolog" | cstm /usr/contrib/bin/kmeminfo sam -> Performances Monitor -> System Properties ===== Récupérer la configuration hardware des CPU ===== echo "itick_per_usec/D" \ |adb -k /stand/vmunix /dev/kmem \ |tail -1 \ |awk '{ print $2 , "\bMhz" }' :!: ne fonctionne qu'avec HP ≤ 11.11 echo "selclass qualifier cpu;info;wait;infolog" | cstm Eventuellement : icod_stat ===== Récupérer la configuration systeme ===== echo "selclass qualifier system;info;wait;infolog" | cstm ===== Récupérer la population de carte PCI ===== HP-UX 11i-v1 (11.11) rad -q HP-UX 11i-v2 (11.23) olrad -q ===== GSP ===== [rnsd5-adm] MP:CM> ps Display detailed status of the selected MP bus device. The following MP bus devices were found: +---+----+-----+-------+-------+-----------+ | | | | | | | | | | Sys | | IO | Bulk Pwr | |Cab| MP |Bkpln| Cells |Chassis| Supplies | | # |M S| |0 1 2 3| 0 1 |0 1 2 3 4 5| +---+----+-----+-------+-------+-----------+ | 0 |* *| * |* * * *| * * |* * * * * *| +---+----+-----+-------+-------+-----------+ You may display detailed power and hardware status for the following items: T - Cabinet S - System Backplane G - MP (Core I/O) P - IO Chassis C - Cell Select Device: T HW status for rx8640 cabinet : FAILURE DETECTED Master/Slave failover is Enabled Power switch is on Right Door is closed Top Door is closed Left Door is closed Total Power Available 6000 VA Total Power Needed 3997 VA Power Redundancy : redundant Power Viability : viable Power Status ---------------+-----+-------+-------+-----------+ | | | | | | Sys | | IO | Bulk Pwr | |Bkpln| Cells |Chassis| Supplies | | |0 1 2 3| 0 1 |0 1 2 3 4 5| ---------------+-----+-------+-------+-----------+ Populated | * |* * * *| * * |* * * * * *| Enabled | * |* * * *| * * |* * * * * *| Power OK | * |* * * *| * * |* * * * * *| Warning/Fault | | | | | Attention LED | | | | | AC Line status: Line A0 Present Line B0 Present Line A1 Present Line B1 Present -- Press to continue, or 'Q' to Quit -- Front Fan Speed : normal Rear Fan speed : normal I/O Bay Fan Speed : normal Temperature state : normal Main Fan Redundancy : redundant I/O Fan Redundancy : redundant Overtemp Shutdown Enabled | BPS | PCI | | Fans | Fans | | 0 1 2 3 4 5 | 0 1 2 3 4 5 | +-----------+-------------+-------------+ Populated | * * * * * * | * * * * * * | Failing | | | Failed | | | | Standby/Main Fans | | 1 1 1 1 1 1 1 1 1 1 2 | | 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 | +-----------+-------------------------------------------+ Populated | * * * * * * * * * * * * * * * * * * * * * | Failing | | Failed | | | Cell Fans | | CPU C | | 0 1 2 3 C | +-----------+------------+ Cell 0 | | Populated | * * * * * | Failing | | Failed | | Cell 1 | | Populated | * * * * * | Failing | | Failed | | Cell 2 | | Populated | * * * * * | Failing | | Failed | * | Cell 3 | | Populated | * * * * * | Failing | | Failed | |