====== Cartes ILO ======
Une fois loggé sur la carte ILO on active la console via la commande :
remcons
On peut réinitialiser la carte ILO :
reset map1
Ou bien le serveur :
reset system1
On peut utiliser le package //hponcfg// sur les machines de marque HP pour récupérer la conf ILO ou la mettre à jour :
Récupérer la conf :
hponcfg -w ilo.conf
Appliquer la conf :
hponcfg -f ilo.conf
====== Cartes DRAC ======
=== Récupérer la conf IP ===
++++racadm getsysinfo|
RAC Information:
RAC Date/Time = Mon Jul 28 08:49:40 2008
Firmware Version =
Firmware Build =
Last Firmware Update =
Hardware Version =
Current IP Address = 10.255.61.39
Current IP Gateway = 10.255.60.1
Current IP Netmask = 255.255.252.0
DHCP Enabled = 0
MAC Address = 00:19:b9:be:a4:8e
Current DNS Server 1 =
Current DNS Server 2 =
DNS Servers from DHCP =
Register DNS RAC Name =
DNS RAC Name =
Current DNS Domain =
System Information:
System Model = PowerEdge 6950
System BIOS Version = 1.1.2
BMC Firmware Version = 01.33
Service Tag = XXXXXXX
Host Name = serverl1106861
OS Name = Red Hat Enterprise Linux AS
Power Status = ON
Watchdog Information:
Recovery Action = None
Present countdown value = 0 seconds
Initial countdown value = 0 seconds
++++
=== Modifier la conf IP ===
racadm setniccfg -s 10.255.61.39 255.255.252.0 10.255.60.1
racadm racreset
===== Pour se connecter à la console d'une machine =====
=== DELL Poweredge ===
$ connect com2
Connected to com2. To end type: '^\'
:!: ^\ veut dire : utiliser la combinaison de touches suivantes : C-S-8
=== Message 'com2 currently in use' ===
racadm racreset
Cela reset la carte DRAC et dégage les malotrus mal déconnectés (comprenez ''ceux qui utilisent la croix en haut à droite''). Enfin j'ai quand même regardé que, même en de déloguant proprement, on obtient parfois ce message :-/
===== Reparamétrage du BIOS pour la console texte =====
==== DRAC4 ====
* Config du BIOS
omconfig chassis biossetup attribute=conredirect setting=enable
omconfig chassis biossetup attribute=serialport1 setting=rac
omconfig chassis biossetup attribute=fbr setting=9600
omconfig chassis biossetup attribute=crab setting=enabled
* Config de la DRAC
racadm config -g cfgSerial -o cfgSerialBaudRate 57600
racadm config -g cfgSerial -o cfgSerialConsoleEnable 1
racadm config -g cfgSerial -o cfgSerialConsoleIdleTimeout 0x300c
racadm config -g cfgSerial -o cfgSerialTelnet7fIsBackspace 1
racadm config -g cfgSerial -o cfgSerialSshEnable 1
racadm config -g cfgSerial -o cfgSerialHistorySize 0x2000
* Config du GRUB (/etc/grub.conf)
#splashimage=(hd0,0)/grub/splash.xpm.gz
#hiddenmenu
serial --unit=0 --speed=9600
terminal --timeout=5 serial console
kernel /vmlinuz-2.6.9-67.ELsmp ro root=LABEL=/ console=tty0 console=ttyS0,57600
* Config de l'inittab (/etc/inittab)
CONS:2345:respawn:/sbin/agetty -i -h -L 115200 ttyS1 vt100
==== DRAC5 / DRAC6 ====
* Config du BIOS
omconfig chassis biossetup attribute=extserial setting=rad
omconfig chassis biossetup attribute=fbr setting=9600
omconfig chassis biossetup attribute=serialcom setting=com2
omconfig chassis biossetup attribute=crab setting=enabled
* Config de la DRAC
racadm config -g cfgSerial -o cfgSerialBaudRate 115200
racadm config -g cfgSerial -o cfgSerialConsoleEnable 1
racadm config -g cfgSerial -o cfgSerialSshEnable 1
racadm config -g cfgSerial -o cfgSerialHistorySize 2000
* Config du GRUB (/etc/grub.conf)
#splashimage=(hd0,0)/grub/splash.xpm.gz
# hiddenmenu
serial --unit=1 --speed=115200
terminal --timeout=5 serial console
kernel /vmlinuz-2.6.9-67.ELsmp ro root=LABEL=/ console=tty0 console=ttyS1,115200
* Config de l'inittab (/etc/inittab)
CONS:2345:respawn:/sbin/agetty -i -h -L 115200 ttyS1 vt100
===== Faire un graceful/hard reset ou un power-on/off/cycle =====
racadm serveraction
//powerdown// – Powers down the server module.\\
//powerup// – Powers up the server module.\\
//powercycle// – Issues a power-cycle to the server module.\\
//hardreset// – Issues a hard reset to the server module.\\
//graceshutdown// – Powers down the server module gracefully.\\
//gracepowercycle// – Powers down the server module gracefully (same as the graceshutdown option)\\
===== Infos sur les slots mémoire =====
Commande pour afficher les infos sur les slots mémoire sur les DELL :
omreport chassis memory
Si vous avez des messages d'erreurs vous pouvez relancer les services DELL :
/etc/init.d/ipmi restart
srvadmin-services.sh restart
Pour obtenir d'autres type d'informations :
omreport chassis -?